Glasfaserkabel

A/I-DQ(ZN)H

Glasfaserkabel

Loose tube construction, metal-free, longitudinally watertight, halogen-free, flame retardant

Suited for indoor and outdoor use - for fixed laying in cable ducts, conduits or direct burial

Application
  • FRP-central element
  • jelly-filled loose tubes, SZ-cabling (if necessary with fillers)
  • strength members (aramide yarns)
  • FRNC-outer sheath (1,5 mm) according to IEC 60332-2, UV-resistant, black

 

Fiber / tube colors

PENGG KABEL standard according to “Color codes – Fiber optic cables” in the document “General information” in the download area.
Upon customer request we can also manufacture according to other color codes (DIN, TIA / EIA-598 (MPO), IEC).

 

Standard marking

PENGG KABEL – cable type – fiber count/type – ID number – CPR class CE-marking – meter

 

On request
  • jelly-filled cable core
  • increased tensile strength
  • FRNC-sheath according to IEC 60332-3
  • increased sheath thickness
  • other sheath color
  • colored stripes
  • other marking

 

This data sheet describes a standard type.
Numerous variants are available on request.

tube diameter
mm
number of tubes max. fibers / tube max. number of fibers tensile strength
approx. N
weight
approx. kg/km
outer diameter
approx. mm
fire load
MJ/m
2,0

2,3
2,3
2,3
2,3
2,3
2,3
2,3

2,8
2,8
2,8
2,8
2,8
2,8
2,8

6*

5*
6
8
10
12
16
18

5*
6
8
10
12
16
18

4

12
12
12
12
12
12
12

24
24
24
24
24
24
24

24

60
72
96
120
144
192
216

120
144
192
240
288
384
432

1.500

1.500
1.500
2.000
2.000
3.000
3.000
3.000

1.500
1.500
2.000
2.000
3.000
3.000
3.000

80

85
100
120
150
195
175
195

110
135
160
190
260
245
275

9,5

10,0
10,5
12,0
13,5
15,0
14,5
15,0

11,0
12,0
13,7
15,5
17,3
16,7
17,7

2

2,5
2,5
3
3,5
4
5
6

2,5
2,5
3
4
4,5
5
6

* at lower number of tubes corresponding blind elements are used

Technical data

according IEC EN 60794-6 – Indoor/outdoor optical fibre cables

tensile strength see above table
compressive strength (crush) 2500 N/10 cm
impact 25 Nm
torsion 5 cycles ±360°
kink, cable The cable do not form a kink when a loop is drawn together to a diameter 12 times the cable outer diameter.
min. bending radius R = 20 x D (cable outer diameter)
temperature range storage and transport: -40°C up to +70°C
installation: -5°C up to +60°C
operation: -30°C up to +70°C
water penetration No water on free end.

 