Construction
| Conductor | Plain… |
Outside signalling and communication cables with longitudinal and transverse watertightness
Außenkabel Bahnkabel Telekommunikationskabel CU/PE/VAS/FOL/AL+PE 3x2x1,4
Filling
petrol jelly
Overall Shield, Reinforcement
composite layer (L)
Product Suitability
Bahnkabel Telekommunikationskabel Baltic States
Structure, Laying, Imprint
Construction
| Conductor | Plain annealed copper wire Ø1,4 mm (equal to cross section 1,5mm²) (CU) |
| Insulating | Solid PE (PE) |
| Colour code of the pairs | White – Blue, White – Orange, White – Green, White – Brown, White – Grey, Red – Blue, Red – Orange, Red – Green, Red – Brown, Red – Grey |
| Stranding (UTP) | Conductors are stranded together to pairs, pairs stranded in random arrangement concentrically to the cable core |
| Filling | Filled with petrol jelly (Longitudinally water tight) (VAS) |
| Wrapping | Wrapped with one layers plastic tape (FOL) |
| Outer Sheath | One layer both side coated copolymer aluminium tape, longitudinal with overlap, thickness 0,15 mm (transverse watertight), PE, black, nominal wall thickness according table “dimension” (AL+PE) |
Signature
PENGG KABEL – Type – Year – Meter
Product Dates
| Type | Nomional wall thickness outer sheath [mm] |
Approx. outer diameter [mm] | Approx. cable weigth [kg/km] |
|---|---|---|---|
| 3x2x1,4 | 1,4 | 16,5 | 16,5 |
Technical Details
Technical details (at 20°C)
| Specification | customer spec. & ET 4719 | |
| Conductor loop resistance 1,4mm | ≤12,1 | Ω/km |
| Insulation resistance | min. 10 | GΩkm |
| Mutual capacitance at 800 Hz | ≤60 | nF/km |
| Capacity unbalance at 800 Hz K1 | ≤600 | pF/km |
| Attenuation at 800 Hz | nom. 0,5 | dB/km |
| Characteristic impedance at 800Hz | 340 | Ω |
| Dielectric strength (50 Hz, peak value) | ||
| core/core | 3000 | VAC |
| core/screen | 3000 | VAC |
| Halogen free | according IEC 60754-2 | |
| Minimum bending radius | 10xD | |
| Temperature range | ||
| during installation | -10 up to +60 | °C |
| during operation | -40 up to +70 | °C |
Subject to technical changes.
CPR - Regulations
Construction
| Conductor | Plain annealed copper wire Ø1,4 mm (equal to cross section 1,5mm²) (CU) |
| Insulating | Solid PE (PE) |
| Colour code of the pairs | White – Blue, White – Orange, White – Green, White – Brown, White – Grey, Red – Blue, Red – Orange, Red – Green, Red – Brown, Red – Grey |
| Stranding (UTP) | Conductors are stranded together to pairs, pairs stranded in random arrangement concentrically to the cable core |
| Filling | Filled with petrol jelly (Longitudinally water tight) (VAS) |
| Wrapping | Wrapped with one layers plastic tape (FOL) |
| Outer Sheath | One layer both side coated copolymer aluminium tape, longitudinal with overlap, thickness 0,15 mm (transverse watertight), PE, black, nominal wall thickness according table “dimension” (AL+PE) |
Signature
PENGG KABEL – Type – Year – Meter