Bahnkabel Telekommunikationskabel Baltic States
PE-PE-L ..x2x0,9


C60
0.9
3-30
Bahnkabel Telekommunikationskabel Baltic States
Outside plant signalling cables used for signalling systems with operating voltage from 0,6/1 kV.
Cables up to 30 pairs, solid polyethylene insulated conductors of nominal diameter 0,9 mm. The pairs are stranded into layers to form the cable core that is filled with a waterblocking compound and wrapped with plastic tape. Outher sheath is a aluminium laminated PEsheath for transverse water tightness.
Außenkabel Bahnkabel Telekommunikationskabel PE-PE-L ..x2x0,9
Filling
petrol jelly
Overall Shield, Reinforcement
composite layer (L)
Product Suitability
Bahnkabel Telekommunikationskabel Baltic States
Structure, Laying, Imprint
Construction
Conductor | Plain annealed copper wire 0,9 mm |
Insulation | Solid PE (HDPE) |
Colour code of the pairs | White – Blue, White – Orange, White – Green, White – Brown, White – Grey, Red – Blue, Red – Orange, Red – Green, Red – Brown, Red – Grey, Black – Blue, Black – Orange, Black – Green, Black – Brown, Black – Grey, Yellow – Blue, Yellow – Orange, Yellow – Green, Yellow – Brown, Yellow – Grey, Violet – Blue, Violet – Orange, Violet – Green, Violet – Brown, Violet – Grey, White – Blue, White – Orange, White – Green, White – Brown, Red – Black |
Stranding | Cores are stranded together to pairs, pairs are stranded in concentric layers |
Filling | Filled with petrol jelly |
Wrapping | Wrapped with one layer of PETP foil, longitudinal with overlap |
Inner sheath | One layer copolymer aluminium tape, longitudinal with overlap, PE (LDPE), black |
Outer sheath | PE (LDPE), black, nominal wall thickness 1,4 mm |
Signature
PENGG KABEL – Type – Year – Meter
Product Dates
Type | Nomional wall thickness outer sheath [mm] |
Approx. outer diameter [mm] | Approx. cable weigth [kg/km] |
---|---|---|---|
3x2x0,9 10x2x0,9 14x2x0,9 20x2x0,9 24x2x0,9 28x2x0,9 |
1,4 1,4 1,4 1,4 1,4 1,4 |
10,7 16,8 18,2 20,1 22,2 22,7 |
126 352 402 527 633 692 |
Technical Details
Technical details (at 20°C)
Specification | customer spec.+ PENGG standard | |
Conductor loop resistance | ≤29 | Ω/km |
avg. 27,7 +/-1 | Ω/km | |
Resistance unbalance | ≤2 | % |
Insulation resistance | min. 20 | GΩkm |
Mutual capacitance at 800 Hz pair cable | max. ≤60 | nF/km |
avg. 52 +/-5 | nF/km | |
Capacity unbalance pair/pair | ≤145 | pF/km |
Near-end crosstalk (NEXT), 800 Hz | nom. ≥78 | dB (300m) |
Attenuation at 800 Hz | 0,75 | dB/km |
Dielectric strength (3 sec) | 3500 | VDC |
Cable operating temperature | -40 up to +60 | °C |
Cable life time | min. 30 | years |
Halogen free | according IEC 60754-2 | |
Cables produced | according to IEC 60228 and IEC 60287 |
Subject to technical changes.
CPR - Regulations
Construction
Conductor | Plain annealed copper wire 0,9 mm |
Insulation | Solid PE (HDPE) |
Colour code of the pairs | White – Blue, White – Orange, White – Green, White – Brown, White – Grey, Red – Blue, Red – Orange, Red – Green, Red – Brown, Red – Grey, Black – Blue, Black – Orange, Black – Green, Black – Brown, Black – Grey, Yellow – Blue, Yellow – Orange, Yellow – Green, Yellow – Brown, Yellow – Grey, Violet – Blue, Violet – Orange, Violet – Green, Violet – Brown, Violet – Grey, White – Blue, White – Orange, White – Green, White – Brown, Red – Black |
Stranding | Cores are stranded together to pairs, pairs are stranded in concentric layers |
Filling | Filled with petrol jelly |
Wrapping | Wrapped with one layer of PETP foil, longitudinal with overlap |
Inner sheath | One layer copolymer aluminium tape, longitudinal with overlap, PE (LDPE), black |
Outer sheath | PE (LDPE), black, nominal wall thickness 1,4 mm |
Signature
PENGG KABEL – Type – Year – Meter