Bahnkabel Telekommunikationskabel Baltic States

PE-PE-L ..x2x0,9

C60

0.9

3-30

Bahnkabel Telekommunikationskabel Baltic States

Outside plant signalling cables used for signalling systems with operating voltage from 0,6/1 kV.

Cables up to 30 pairs, solid polyethylene insulated conductors of nominal diameter 0,9 mm. The pairs are stranded into layers to form the cable core that is filled with a waterblocking compound and wrapped with plastic tape. Outher sheath is a aluminium laminated PEsheath for transverse water tightness.

Non-binding inquiry
Structure, Laying, Imprint
Construction
Conductor Plain annealed copper wire 0,9 mm
Insulation Solid PE (HDPE)
Colour code of the pairs White – Blue, White – Orange, White – Green, White – Brown, White – Grey, Red – Blue, Red – Orange, Red – Green, Red – Brown, Red – Grey, Black – Blue, Black – Orange, Black – Green, Black – Brown, Black – Grey, Yellow – Blue, Yellow – Orange, Yellow – Green, Yellow – Brown, Yellow – Grey, Violet – Blue, Violet – Orange, Violet – Green, Violet – Brown, Violet – Grey, White – Blue, White – Orange, White – Green, White – Brown, Red – Black
Stranding Cores are stranded together to pairs, pairs are stranded in concentric layers
Filling Filled with petrol jelly
Wrapping Wrapped with one layer of PETP foil, longitudinal with overlap
Inner sheath One layer copolymer aluminium tape, longitudinal with overlap, PE (LDPE), black
Outer sheath PE (LDPE), black, nominal wall thickness 1,4 mm

 

Signature

PENGG KABEL – Type – Year – Meter

 

Product Dates
Type Nomional wall thickness
outer sheath [mm]
Approx. outer diameter [mm] Approx. cable weigth [kg/km]
3x2x0,9
10x2x0,9
14x2x0,9
20x2x0,9
24x2x0,9
28x2x0,9
1,4
1,4
1,4
1,4
1,4
1,4
10,7
16,8
18,2
20,1
22,2
22,7
126
352
402
527
633
692
Technical Details
Technical details (at 20°C)
Specification customer spec.+ PENGG standard
Conductor loop resistance ≤29 Ω/km
avg. 27,7  +/-1 Ω/km
Resistance unbalance ≤2 %
Insulation resistance min. 20 GΩkm
Mutual capacitance at 800 Hz     pair cable max. ≤60 nF/km
avg. 52  +/-5 nF/km
Capacity unbalance     pair/pair ≤145 pF/km
Near-end crosstalk (NEXT), 800 Hz nom. ≥78 dB (300m)
Attenuation at 800 Hz 0,75 dB/km
Dielectric strength (3 sec) 3500 VDC
Cable operating temperature -40 up to +60 °C
Cable life time min. 30 years
Halogen free according IEC 60754-2
Cables produced according to IEC 60228 and IEC 60287

 

Subject to technical changes.

CPR - Regulations
Construction
Conductor Plain annealed copper wire 0,9 mm
Insulation Solid PE (HDPE)
Colour code of the pairs White – Blue, White – Orange, White – Green, White – Brown, White – Grey, Red – Blue, Red – Orange, Red – Green, Red – Brown, Red – Grey, Black – Blue, Black – Orange, Black – Green, Black – Brown, Black – Grey, Yellow – Blue, Yellow – Orange, Yellow – Green, Yellow – Brown, Yellow – Grey, Violet – Blue, Violet – Orange, Violet – Green, Violet – Brown, Violet – Grey, White – Blue, White – Orange, White – Green, White – Brown, Red – Black
Stranding Cores are stranded together to pairs, pairs are stranded in concentric layers
Filling Filled with petrol jelly
Wrapping Wrapped with one layer of PETP foil, longitudinal with overlap
Inner sheath One layer copolymer aluminium tape, longitudinal with overlap, PE (LDPE), black
Outer sheath PE (LDPE), black, nominal wall thickness 1,4 mm

 

Signature

PENGG KABEL – Type – Year – Meter

 

In the field of cable assembly, we offer comprehensive services.

Learn more

Whether fiber or copper cables: 
We connect it for you!